Underfloor heating and heat pumps: why low flow temperatures matter

If you are planning a heat pump, the way heat gets into each room matters as much as the heat pump itself. Underfloor heating is the emitter heat pumps are most comfortable with. Here is why, and what to plan.
Why flow temperature matters
A heat pump moves heat from the outside air into the water in your heating system. The cooler that water needs to be, the less work the heat pump does and the more heat it delivers for each unit of electricity. That is why European heat pump ratings are quoted at a low-temperature point of 35°C and a medium-temperature point of 55°C.
Underfloor heating runs cool
A floor has a much larger surface than a radiator, so it can heat a room with much cooler water. Design guidance from the Sustainable Energy Authority of Ireland uses typical flow temperatures of 35°C for underfloor heating, 45°C for fan-assisted radiators and 55°C for standard radiators. The MCS Heat Emitter Guide, used by certified heat pump installers in the UK, notes that heat pump performance is best when low-temperature emitters are used.
What to plan before you start
A room-by-room heat loss calculation. It sets how much heat each room needs, which decides pipe spacing and whether underfloor heating alone is enough. Our sister company, The Essential Connection, carries out heat loss surveys.
Insulation under the pipes, so the heat goes up into the room rather than down into the ground.
The floor build-up: screed depth, or a low-profile system where floor height is limited, and how it meets door thresholds and existing floors.
The floor finish. Stone and tiles pass heat easily; thick carpet and some timber floors need lower surface temperatures. See floor finishes over underfloor heating.
Mixed systems. Many homes have underfloor heating downstairs and radiators upstairs. The radiators then need sizing for low water temperatures too.
Controls. A heat pump with weather compensation and room thermostats runs the floor at the lowest temperature that keeps each room comfortable.
Grants
The Boiler Upgrade Scheme can contribute up to £7,500 towards an air source heat pump in England and Wales. The Essential Connection explains how the grant works.
How we work together
Koniu Construction builds the floor: insulation, pipework, screed or low-profile boards, and the finished tiles or flooring. The Essential Connection designs and installs the heat pump and the controls. You deal with one team from the survey to the final floor. Read more about how underfloor heating changes comfort at home, see our underfloor heating service, or book a survey visit (£150).